Writers' Community!
Home News Business Science & Technology Life Style
Front Page Page Two Columnists Submit an Article FAQs Contact Author Login
Article Submission
We Need YOUR Articles!
We'll Promote Them for FREE!

Author Login

New Authors
Register Here


Now Serving 5,573 Authors
48,496 Quality Articles
& 3,254 Current Users Online!
Featured Authors
Robert Melaccio, Sr. (6,523)
Ira Coffin (985)
Walter Rhett (2,706)
Jeff Brown (8,038)
Alf Gordon (1,353)
Nicole Beurkens (156)
David Tanguay (7,592)
Joel Hendon (4,915)
Terry Mitchell (2,813)
Rob Lafferty (123)
Arlene Wright-Correll (10,175)
Jane Bullard (2,081)
Avis Ward (13,599)
Richard Nicastro (2,530)

View All Featured Authors
Most Recent
Your Ultimate Guide in Buying Fire Extinguisher

Reasons Why You Should Get Fire Extinguisher Cabinets

How to Protect Business from Fire Caused by Deep Fryers

How To Keep Moisture From Damaging Your Compressed Air System

Just the Fax Ma'am, Choosing a Fax Machine

Automation Creates Demand for More Tech-Savvy Shipping and Receiving Clerks

Comparing Binding Machine Punches Based on Punching Capacity

Choosing the Right Rotary Trimmer for Your Cutting Needs

Choosing the Right Ream Cutter or Stack Cutter for Your Office

Choosing the Right Laminating Trimmer for Your Needs

Home » Categories » Business » Business Equipment » How To Keep Moisture From Damaging Your Compressed Air System » Printer Friendly

Tommy McGuire

How To Keep Moisture From Damaging Your Compressed Air System

Rated 3.5 out of 5
No Reader Ratings Available ?
Rate It  /  View Comments  /  View All Articles submitted by Tommy McGuire
Submitted Wednesday, September 24, 2008
Tommy McGuire (560)
Tommy McGuire

McGuire Air Compresssors, Inc.
Log in to become a member of Tommy McGuire's Fan Club!


Ask a Question:
Can water or moisture be damaging my compressed air system?

Answer:
Absolutely!  Water corrodes pipes, valves, machinery controls.  None of this is good.  When controls malfunction, production can stop or product can be impaired and all this costs you time and money.
Water in Aerosol or Vapor form is more difficult to remove and requires the use of a Compressed Air Dryer.

Ask a Question:
How does water or moisture get into my compressed air?

Answer:
Through your Compressor inlet.
Water vapor (humidity-moisture) enters the air system through the air compressor inlet air filter. The air compressor sucks in approximately 7 cubic feet of atmospheric air at 0 psig, and that volume of air is compressed into 1 cubic feet of air at 100 psig. The water vapor (humidity-moisture) that was in the 7 cubic feet of atmospheric air is now compressed into 1 cubic feet of compressed air. 

There are 3 forms of water in compressed air:
Liquid water
Aerosol (mist)
Vapor (gas)
Any of these forms of moisture can create problems down the road in equipment or may create serious problems in your process or end product today.

Ask a Question:
How to tell if you need a Refrigerated Air Dryer?

Answer:
If you are experiencing the following problems...then you may need a Refrigerated Compressed Air Dryer:
Liquid water is in your air lines and hoses
Water vapor sprays out of your tool exhaust
Pipe lines corrode and rust
Paint Sprayer has water spots in the paint
Your Equipment Manufacturer specifies "DRY AIR"

Ask a Question:
What can help remove moisture from my Compressed Air System?

Answer:
Refrigerated Air Dryers can be one of the best solutions to removing water and moisture from your Compressed Air System.

Ask a Question:
How does a Refrigerated Air Dryer Work?

Answer:
• The refrigerated air dryer cools the incoming compressed air first in an air-to-air heat exchanger where the outgoing cool dry air pre-cools the hot incoming air and condenses some moisture out.
• Then the incoming air enters an air-to-refrigerant heat exchanger where the air is cooled to 38º F by the liquid refrigerant. This process causes the moisture to condense into liquid water and it is drained away. The out going air then enters the air-to-air heat exchanger and is warmed up to keep the outside of pipes from sweating.
• The refrigeration compressor pumps hot hi-pressure gas refrigerant (Freon) into the condenser which transfers the heat from the refrigerant gas to the ambient air as the gas condenses into a liquid.
• The liquid refrigerant (Freon) is then metered to a cold low pressure where it enters the air-to-refrigerant heat exchanger and the heat from the hot compressed air is adsorbed into the cold refrigerant (Freon). The refrigeration compressor then sucks low pressure hot gas refrigerant (Freon) into the refrigeration compressor and the cycle starts over again.

BOTTOM LINE:
If you are experiencing unwanted moisture and water in your Compressed Air System, then seriously consider the addition of a Refrigerated Air Dryer. After all - what is the best way to spend your money --on constant maintenance, failed equipment and ruined end products or by investing in a properly sized compressed air dryer?

Experience proves it!  Remove Water and Moisture to improve Compressed Air Quality & Efficiency!

Increase Production - less down time due to moisture related equipment problems
Reduce loss due to inferior products ruined by moisture in lines
Bring more profit to your bottom line






Reprint Rights

Log in to become a member of Tommy McGuire's Fan Club!

Comments on this article:
No comments yet.


Was this article helpful to you? Leave a Public Comment or Question:

 

This Article has been viewed 77 times.
Article added to SearchWarp.com on Wednesday, September 24, 2008
View other articles written by Tommy McGuire (560)
Tommy McGuire


If you found this article interesting, you may want to check out:

Disclaimer:  All information on this site is provided for informational purposes only! By no means is any information presented herein intended to substitute for the advice provided to you by any health care or other professional or organization.


Today's Most Popular
Why are there Lines on my Copies?

How to Make Rubber Stamps- Comparing Methods of Manufacture

Buying a Mannquin? Tips so You Don't Get Stiffed - Vol 2

How To Program An Avaya Partner Phone

SAP vs. Oracle

Restaurant 86 Item Countdown Feature - A Point of Sale Solution To An Old Problem

Your Copier Lease and Sarbanes Oxley - What Your Copier Vendor Doesn’t Want You to Know

The Flexibility of Roll-Top Computer Desks

Wireless System Monitor: Update

Vending Machine Rental - How To Profit From One

Home  |  Page Two  |  FAQ's  |  Contact  |  Terms of Service  |  Article Submission Guidelines  |  Writers' Contests  |  Privacy  |  Mission / About
Copyright © 1999-2008 SearchWarp.com, All Rights Reserved - SearchWarp.com is an IcoLogic, Inc. Company