One of the Most Frequently Seen Electrical Defects

Following the Trail of Open Windows

Social Security Theft - Learn How Social Security Theft Devastated This Individual

Medical Identity Theft - Are You Protecting Your Identity?

Protecting your identity - 5 Tips for Protecting Your Identity From Employment Fraud

Medical Identity Theft - Medical Identity Theft is Becoming a Nightmare

Company Identity Theft - Are You Scared of Company Identity Theft?

Causes of Identity Theft - How Many Causes of Identity Theft?

Beauty Salon Industry Suffering?

Home » Categories » Professional Services » Other Professional Services » One of the Most Frequently Seen Electrical Defects » Printer Friendly

Joe Farsetta

One of the Most Frequently Seen Electrical Defects

Rated 3 out of 5
No Reader Ratings Available ?
Rate It  /  View Comments  /  View All Articles submitted by Joe Farsetta
Submitted Tuesday, September 29, 2009
Joe Farsetta (78)
Joe Farsetta

Inspection Arbitration Services
Log in to become a member of Joe Farsetta's Fan Club!


DID YOU KNOW...

... that one of the most frequently seen electrical defect has to do with the wiring of electrical sub-panels? It's true. A majority of sub-panels, which are secondary electrical panels wired to the main electrical panel, require four-conductor feeder cables. Once these conductors reach the sub-panel, the grounded (neutral) conductor and grounding (bare-ground) conductor must be SEPARATED. In fact, the neutral conductor must be on its own termination bus bar, which is not in any way connected to the panel case, or housing. The ground conductor must be connected to the case. In addition to this, each individual branch circuit cable's neutral and ground conductors must also be separated, and correctly terminated onto the corresponding terminal bus bar. Often, inspectors see these wired co-mingled and terminated on a single terminal bus bar. This is a common electrical defect, which related directly to safety, and which must be corrected via re-termination. Sometimes, the feeder cable has an insufficient number of conductors (four are needed) which makes correcting this defect more costly and complicated.



tweet this!



Reprint Rights

Log in to become a member of Joe Farsetta's Fan Club!

No comments yet.


Was this article helpful to you? Leave a Public Comment or Question:

This Article has been viewed 7 times.
Article added to SearchWarp.com on 9/29/2009 2:20:44 PM.
View other articles written by Joe Farsetta (78)
Joe Farsetta


If you found this article interesting, you may want to check out:

Disclaimer:  All information on this site is provided for informational purposes only! By no means is any information presented herein intended to substitute for the advice provided to you by any health care or other professional or organization.


Today's Most Popular
The Top 10 Tips for Dealing with Problem Behavior in the Workplace

Can You Really Get a US Passport in Days?

Increase your Business Performance by Setting Performance Standards and Expectations for your Employees

10 Critical Elements of a Successful Business

How Well Do Employers Really Know What Their Staff Want?

Start with a school radio station

10 Ways to Beef Up your Leadership Skills

Oil Pictures-Transport and Problems

Translation Matters: Important Tips for Translation Service Buyers

Sustainable Architecture

Viewed from Cache. Load Time: 0.016.

Home  |  Page Two  |  FAQ's  |  Contact  |  Terms of Service  |  Article Submission Guidelines  |  Questions & Answers  |  Privacy  |  Mission / About
Copyright © 1999-2009 SearchWarp.com, All Rights Reserved - SearchWarp.com is an IcoLogic, Inc. Company