Writers' Community!
Home News Business Science & Technology Life Style
Business Home Economy Investing Energy Employment Real Estate Industry Finance
Article Submission
We Need YOUR Articles!
We'll Promote Them for FREE!

Author Login

New Authors
Register Here


Now Serving 5,612 Authors
48,599 Quality Articles
& 5,686 Current Users Online!
Featured Authors
Robert Melaccio, Sr. (6,428)
Terry Mitchell (2,881)
Mike Fak (6,526)
Walter Rhett (2,655)
David Pekrul (802)
Barbara Clark (479)
Teresa Ortiz (4,920)
Jane Bullard (2,004)
Tex Norman (4,421)
Janice Tracy (148)
David Tanguay (7,680)
Mogama (12,506)
Joel Hendon (4,870)
Susan Thom (9,120)

View All Featured Authors
Most Recent
FIFA World Cup 2010 South Africa - Scaffold and Formwork Contractors

How to Choose a Contractor

Health and Safety Guidelines in the Construction Sector

Balloon Framing Gable Walls

Disrespect in the Workplace Leads Workers to Organize

How to Make a Profit in the Heavy Construction Industry

For Developers, Going Green Has Never Been So Beautiful

The Details of the 2008 California Building Code Changes

Care Of Wear And Tear To The Roof

All About Used Gutter Machines

Home » Categories » Industry » Construction » Electric Generator and Power Generator Safety Tips » Printer Friendly

Electric Generator and Power Generator Safety Tips

Rated 3.5 out of 5
No Reader Ratings Available ?
Rate It  /  View Comments  /  View All Articles submitted by Ann Knapp
Submitted Friday, September 15, 2006
Ann Knapp (66)
XG Power
Log in to become a member of Ann Knapp's Fan Club!


When buying a diesel generator make a list of the lights and equipment that will be running off the generator. Total the wattage requirements to determine the capacity of the generator. Compare wattage requirement and the price of the generator. If the generator is to be connected directly to the electrical system, then it is advisable to hire a qualified technician to install the transfer switch. Ensure that the generator has adequate storage capacity, longer usage time at a stretch, overload protection and auto shut off facility.

Portable generators are critical to have in emergencies or for use in areas where there is no traditional electricity. Always keep in mind there are safety issues related to the proper use of the generators. Portable generators can cause electrocution if they are left in the rain or sitting in water. Keep the generator under a canopy where it is protected, but not totally enclosed. It must still have adequate ventilation. Never touch the generator when you are standing in water or your hands are wet. Never run extension cords through water of any kind. Keep all unauthorized people away from the unit while it is operating.

Make sure all extension cords are of high enough rating for whatever load they are to carry. Also check for fraying, exposed wires or areas where the cord may be underneath something else and is hard to see. Many people will put cords under rugs or furniture, but this can harm the cord and hide any defects in the cord.

Check cords when the portable generator is operating to make sure they are not overheating. Overheating is an indication of too much load for the cord or else damaged wires inside the cord. Even though the cords may be rated for the load you have, if compressors are turning on and off, the load may be temporarily increasing beyond the rating.

Even with the best alternative system such as solar energy or wind energy, sometimes the weather may not cooperate and land us in darkness when the main power source fails. To keep our power system running, a backup engine generator may be just the thing. For businesses with sensitive computer networks, or homes with critical medical equipment, a back up power system such as a diesel generator may be necessary even when grid power is available.

When buying a diesel generator make a list of the lights and equipment that will be running off the generator. Total the wattage requirements to determine the capacity of the generator. Compare wattage requirement and the price of the generator. If the generator is to be connected directly to the electrical system, then it is advisable to hire a qualified technician to install the transfer switch. Ensure that the generator has adequate storage capacity, longer usage time at a stretch, overload protection and auto shut off facility.

Here is an example of a electric generator you can find at XG Power. This one is a 6700-watt Electric Generator 110 / 240 volt with electric start

Our generator packs plenty of power to run heavy-load equipment like heaters or air compressors. Auto decompression ensures easy starting. Dependable, maintenance-free ignition and brushless alternator. Large, super-quiet muffler. Black, tubular steel frame and easy-to-read fuel gauge. This super-fuel-efficient generator gets up to 11 hours of continuous operation on a tank of gas.

Generator Specifications:

* Type : Brushless AVR - Single Phase

* AC Frequency : 60 HZ

* Maximum AC Output : 6700 Watts

* Rated AC Output : 6000 Watts

* Rated / Maximum AC Current : 50.0 / 55.0 Amps @ 120 Volts

* Driving Method : Direct

* Two 110 volt and two 220 volt outlets

Engine specifications:

* Type : 4-Stroke, OHV, Air Cooled

* Rated Horsepower : 12HP @ 3,600 rpm

* Bore x Stroke : 66mm x 50mm

* Displacement : 357cc / 12HP

* Cooling : Forced Air

* Lubrication : Wet Sump

* Oil Capacity : 0.63 qt

* Starting Method : Recoil

* Ignition System : Transistor Controlled

* Fuel Tank Capacity : 5.5 gal (20.8 Litres)

* Recommended Fuel : Unleaded Regular

* Continuous Operating Hours : 11.3

* Dry Weight : 185 lb (84kgs)

* Noise Level @ 25 ft : 73.5 dBA

* Package size: 27 in.L x 21 in.W x 22.5 in.H

Professional grade tools and equipment at everyday low discount prices. Visit us at http://www.xgpower.com or call 908-534-2117.






Reprint Rights

Log in to become a member of Ann Knapp's Fan Club!

Comments on this article:
No comments yet.


Was this article helpful to you? Leave a Public Comment or Question:

 

This Article has been viewed 404 times.
Article added to SearchWarp.com on Friday, September 15, 2006
View other articles written by Ann Knapp (66)


If you found this article interesting, you may want to check out:

Disclaimer:  All information on this site is provided for informational purposes only! By no means is any information presented herein intended to substitute for the advice provided to you by any health care or other professional or organization.


Today's Most Popular
Types of CertainTeed Roof Shingles

Solid Surface vs Cultured Marble. What are the differences?

How To Find A Roof Leak

All About Copper Roof Shingles

Constuction Job Site Safety Audit - 9 Common Construction Site Safety Issues

Roof Preparation before Installing Roof Shingles

How To Choose The Right Shingle For Your House

Types of Flat Roofing Materials

The Lowdown on Roof Decking

Equipment Numbering and Categorizing - An Effective Approach

Home  |  Page Two  |  FAQ's  |  Contact  |  Terms of Service  |  Article Submission Guidelines  |  Writers' Contests  |  Privacy  |  Mission / About
Copyright © 1999-2008 SearchWarp.com, All Rights Reserved - SearchWarp.com is an IcoLogic, Inc. Company